Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block

Product Details
Customization: Available
Application: PCB, Cable, Computer, Communication, Car, Mobile Phone, Integrated IC, Wer Supply, Battery
Environmental Protection: General
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (33)
  • Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
  • Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
  • Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
  • Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
  • Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
  • Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Find Similar Products
  • Overview
  • Product Information
  • Exhibitions
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
BCC
Connection Mode
Push-Pull Connection
Contact Termination Form
Pressure Welding
Type
Screw
Character
High Temperature Resistance
Production Process
Ceramic
Interface Type
DC/DC
Brand
Jpci
Selling Units
Single Item
Take Care
Not Protected Against Electrical Shocks
Product Name
Steatite Connection Blocs
Conductor Size
5-10AWG
Number of Contacts
1-10
Norm
6mm2
Specification
8.8X4.6X3.1cm
Trademark
Ultimheat
Origin
Guangdong, China
HS Code
8536909000
Production Capacity
50000

Product Description

Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Product Information
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Flexible mineral-insulated cables are designed to provide optimum fire resistance. They generally use mica-based insulation and special silicones, and they are designed to give the ultimate fire performance. Used in power and control circuits, they are providing circuit integrity during a 15 to 180 minutes fire depending of models. They usually have a continuous operating temperature up to 200°C (390°F). They are used in places where it is important to have an interrupted power supply in case of fire. These applications are found in railway stations and underground rail systems, road and rail tunnels, airports, public lighting, car parks, public service buildings, shopping malls, schools, hospitals, hotels, theatres, churches, power distribution and sub circuits, fire alarms and emergency, lifts and escalators lighting. They also have some applications in high temperature situations like foundries, power stations, boiler houses, iron and steel industries, marine and ship buildings, offshore installations.
These terminal blocks provide an economical solution for fire-resistant connection of mineral-insulated flexible cables with an outside diameter of less than 8.5mm and greater than 3.7mm. In sections 1.5mm² and 2.5mm² two cables can be connected to the same terminal. Only one can be connected in 4mm² and 6mm²
- They don't require special termination of the cable, but simply the stripping of the conductor on 8 to 10mm.
- They can be used inside buildings, under pollution conditions 3
- They provide protection against accidental electrical contact.- They ensure the integrity of the electrical circuit for 3 hours at 950°C (1740°F).
- With and ingress protection class IP31, they are not intended for outdoor connections, or in areas where there is a risk of falling or splashing water or liquids.-They are not usable in explosive areas.

Typical insulation resistance between two terminals:
at 100°C (212°F): 1500 MΩ
at 500°C (900°F): 1000 MΩ
at 700°C (1290°F): 650 MΩ
at 900°C (1650°F): 10 MΩ
Dielectric strength: Higher than 6000V at 20°C
Screws: M4x8, 304 stainless steel, with spring washer against loosening at high temperature. Recommended torque 13~20 DaN.cm
Two possible types of screw heads: Phillips or slot upon DIN84
Terminals: 304 Stainless steel
Saddles: 304 Stainless Steel, with or without safety tab against wire shearing
Max wire gauges (per terminal, wires inserted between saddle and connector plate): - 1 single flexible conductor in 10 mm² (AWG8) or 6mm² (AWG10) whose strands must then be divided into two on either side of the screw.- One or two flexible conductors in 4mm²
(AWG 12), 2.5mm² (AWG14), 1.5mm² (AWG16)- One or two solid conductors in 6mm² (AWG10), 4mm² (AWG 12), 2.5mm² (AWG14), 1.5mm²
(AWG16).
Current carrying capacity: 32A per terminal
Maximum operating voltage: 750V, in pollution class 3. (Pollution class 3 defines micro environmental conditions causing conductive pollution, or when a non-conductive pollution can become it in case of condensation).
Insulation distances: Greater than 10mm between mounting face and terminals, between terminals, and 6.4mm between two connection blocks mounted side by side.
Live parts: Not protected against accidental electrical contact.
Important note: These terminal blocks must imperatively be fixed in order to prevent their movement for any reason in the box in which they are mounted, and consequently put them in a position where the insulation distances are no longer respected.
Maximum ambient temperature:
- Permanent: 500°C (900°F)
- In peak short duration: 700°C (1292°F)
- Fire: 900°C (1650°F) for two hours(Afterwards equipment must be replaced, but it retains its main characteristics during the fire)
The temperature resistance values of the stainless-steel terminals were validated by wire pull tests according to EN 60998,performed after 48H at 500°C (930°F) and 90 minutes at 700°C (1290°F).
Partially applicable standards: (IEC) EN 60998-1; (IEC) EN 60998-2-1
Caution: Special care must be taken to avoid electric shock. These terminal blocks are not usable in places accessible without tools. They must be mounted in protective boxes. Respect the distances in the air of at least 6mm between the parts under tension and the walls of the protective case. Other rules may apply according to local safety regulations.
Options: These terminal blocks can be made with brass or nickel terminals and saddles (MOQ apply and references on request). In these two configurations, the maximum permissible intensity per terminal rises from 37A to 53A, and the temperature resistance conditions are modified as follows:
 
Material
 Permanent temperature
 Peak Temperature
 Fire conditions Temperature
 
Brass
 230°C (450°F
 450°C (840°F
Not resistant
 
Nickel
 500°C (930°F
 700°C (1290°F)
120 min at 950°C (1740°F
 
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Exhibitions
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Certifications
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
Company Profile
Ceramic Terminal Block 700c Max. Temperature with Cover Shockproof RoHS Terminal Block
JPCI Controls originated from the French family-owned company founded in 1972, our company was founded in 2000, headquartered in Gaoming District, Foshan City, Guangdong Province, China, which is specialized in the design and production of mechanical thermostats, safety devices and electric heating systems for domestic and industrial use. JPCI owns an internationally renowned brand, ULTIMHEAT, and has a subsidiary in Lyon, France.After more than 50 years of development, JPCI has become a research and development enterprise which is deeply exploring the international market.
 
JPCI Controls covers an area of 30,000 square meters, has more than 300 employees, including 30 professional R & D and laboratory employees, and produces more than 6 million products per year, with more than 10,000 product models. Our production has achieved full vertical integration to ensure quality control at each stage, our company has more than 1000 sets of testing equipment such as ultraviolet aging testing machine, motor loading machine, hydraulic hi-pot bursting testing machine to strictly monitor product quality.
 
JPCI Controls has always adhered to the values of innovation, listening, responding and continuous improvement to ensure that products can achieve the best quality. JPCI holds 250 patents and applies for an average of 20 patents per year. Won the national high-tech enterprises and passed the system certification ISO9001, ISO14001, ISO45001; It has a 750 self-built laboratory and has passed the ISO17025 laboratory certification of TUV&UL.
 
JPCI Controls is driven by innovation, guaranteed by quality, and takes environmental protection as its responsibilitylooking forward to working with you to create a better future.
 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier